Infiltration Test Results
























                                                                                                                                        A                                               B                                    C



                                                                                                                                                                                                                A. YVWD hydrant setup at
                                                                                                                                                                                                                     Oakwood Circle
                                                                                                                                                                                                                B. 4" fire hose above test site
                                                                                                                                                                                                                C. Setting up flow control skid
                                                                                                                                                                                                                     in excavation prior to filling;
                                                                                                                                                                                                                     two float valves on 2"
                                                                                                                                                                                                                     discharge lines and high
                                                                                                                                                                                                                     and low water level alarm
                                                                                                                                                                                                                     sensors
                                                                                                                                                                                                                D. Initial fill of test basin (Day 1)
                                                                                                                                                                                                                E. Consistent silt with fine to
                                                                                                                                                                                                                     medium sand (0-5 feet)






                                                                                                                                                 D                                                      E



                                                    Test Start  Jul-09-2018
                                                                                                                                                  Conclusions:
                                                    Test End    Jul-23-2018                             YVWD Hydrant                              - Results of infiltration testing indicate that the site is suitable for recharge.
                                  Basin Dimensions (L x W) (ft)     32 x 30                                                                       - Full-scale basin initial infiltration rates (based on 50% of measured field-scale testing infiltration
                                    Average Water Height (ft)           2.5                                                                       rates) are estimated at 5.4 feet/day. Long-term infiltration rates (based on 50% of full-scale basin
                                                                                                                                                  initial infiltration rates) are estimated at 2.7 feet/day. While long-term estimates consider
                                                           2
                            Infiltrating Area Basin Bottom (ft )       960                                          Tennessee Street Basin        expected clogging of the basin bottom from SWP water, actual long-term rates will be
                                                           2
                     Infiltrating Area Basin Bottom + Walls (ft )    1,270                                          Test Site                     dependent on the specific site recharge goal and implementation of a basin maintenance plan.
                                  Total Water Added (gallons)      871,782
                                Total Water Added (acre-feet)           2.7                                  " )                                  Recommendations:
                                                                                                                                                  - Depending on size of a full-scale recharge project, pilot scale infiltration test is recommended to
                                                   High (ft/d)        12.3                                                                        identify potential site vadose zone storage capacity constraints due to recharge mounding.
               Infiltration Rate                                                                                                                  - Pilot testing combined with installation of monitoring wells north and south of the Western
                                                   Low (ft/d)           9.2
              (Constant-Head)                                                                                                                     Heights Fault is recommended to confirm groundwater storage benefits from recharge at this location.
                                               Average (ft/d)         10.8
               Infiltration Rate                    High (ft/d)       11.1
                (Falling-Head)                     Low (ft/d)           9.5     ยด                                                                                                                                           Figure 2
                Full-Scale Basin Est. Initial Infiltration Rate (ft/d)  5.4           0                  800 Feet                                                                                                     Tennessee Street
           Full-Scale Basin Est. Long-Term Infiltration Rate (ft/d)     2.7                                                                                                                                                  Basin

                                                                                          Yucaipa Sustainable Groundwater Management Agency - January 23, 2019 - Page 46 of 137
   44   45   46   47   48   49   50   51   52   53   54