Page 172 - Beaumont Basin Watermaster
P. 172

Beaumont Basin Watermaster
                                                                                                                                                                                                       Appendix C

                                                                                                      Pumping Test Data Summary



                                                                                                                               Pumping               Casing                                Estimated
                                                                                                                     Specific                                    Estimated      Trans-
                                       State Well                                         Discharge Drawdown        Capacity      Test     Test Perforation       Aquifer               5   Hydraulic      Data
                                        Number                    Well Name                 (gpm) 1        (ft)                 Length Type     3    Length                   missivity   Conductivity  Source   6
                                                                                                                                                                                 2
                                                                                                                     (gpm/ft) 2                                 Storativity 4  (ft /day)
                                                                                                                                 (days)                (ft)                                  (ft/day)
                                      3S/1E-17C01 Banning CW #C5                                1,100          116         9.5        1.0       0          870           N/A       2,451               3     B
                                      3S/1E-18B01 335504116550401                                 N/A          N/A        N/A         N/A       3          680       0.0033       17,758             26      E
                                           N/A        BCVWD MW-2                                2,805          N/A        N/A         N/A       3          414       0.0026       14,245             34      F
                                      2S/1W-27L01 SGPWA TW-1                                      N/A          N/A        N/A         N/A       3           20       0.0007        9,358            468      C
                                      2S/1W-27B01 BCVWD 16                                        N/A          N/A        N/A         N/A    N/A           N/A      0.0003           N/A            N/A      C
                                           N/A        BCVWD MW-1                                  N/A          N/A        N/A         N/A    N/A           N/A       0.0070          N/A            N/A      C




                                              Notes:
                                                     1  gpm = gallons per minute
                                                     2  gpm/ft = gallons per minute per foot of drawdown
                                                     3  1: Driller's log or short-term pumping test
                                                      2: Hydraulic test on well pump from electric utility
                                                      3: Long-term constant rate test
                                                      0: Unknown
                                                     4  Aquifer storativity based on nearest well with storativity value estimated from a distance-drawdown pumping test
                                                     5  Estimates from test types 0, 1, and 2 based on Theis, 1963. Estimates from test type 3 from original data source.
                                                     6  A: San Gorgonio Pass Water Agency Water Importation Plan, Water Database, 1991

                                                      B: USGS Scientific Investigations Report 2006-5026.
                                                      C: Well completion or testing report

                                                      D: Hydraulic test on well pump from electric utility or driller
                                                      E: Beaumont-Banning Storage Units Boundary Area Groundwater Investigation,1993
                                                      G: Geohydrolic Investigation, Noble Creek Artificial Recharge Study, 2002
                                                     7  N/A = not available
                                                     8  Hydraulic conductivity from layer one based on analysis of flowmeter data.
                                                     9  State well number not available.







                                                                                                                        3 of 3                                                                                3-Apr-15
   167   168   169   170   171   172   173   174   175   176   177