Page 70 - _ 180314 Special Yucaipa GSA Packet
P. 70

Float Valve 4
                                                                                                                                                                               Low-pressure    Pressure
                                                                                                                                                                                   sensor      regulator


                                                                                                                                               OPTIONAL                        PS        PR
                                                                                                                                          Water storage tank                                                                              Manifold
                                                                                                                                               (20,000 gal)                                                                               4-inch pipe connection to
                                                                                                                                                                                                                                          one 2-inch and two 1-inch flow lines

                                                                            Flow
                                                                                                                                                                                                                              Flow meters
                                                                                                                                                                                                                              hand valves



                                                                                                     3-inch fire hose
                                                                             Flow meter +                                                                                                                                          High level switch
                                                                         backflow preventer                                                                                                                                         Lifting eye
                                                      Fire hydrant          and hand valve


                                                                                                                                                                                              3.0’
                                                                                                                                                                                                                                  Float Valve 1
                                                                                                                                                                                              2.5’
                                                                                                                                                                                                                                  Float Valve 2
                                                                                                                                                                                              2.0’
                                                                                                                                                                                                                                  Float Valve 3


                                                                                                                                                                                                                                  Low level switch

                                                                                                                                                                                                                                    Steel gravity base



                                                                                                                                                                                                   30’ x 30’ x 5’ Basin


                                                     Notes: Telemetry calls out when ponded water level is less than 1 foot
                                                               Telemetry calls out when ponded water level is greater than 4 foot
                                                                                                                                                                                                                   3’
                                                               Process Flow
                                                               1. Fire hydrant with back flow preventer is primary water source                                                                            1.5”
                                                               2. Pipeline from hydrant to manifold is 3-inch fire hose (preferred)                                                                                                        Steel gravity base
                                                               3. Optional Water tank outlet could require separate hand valve and flow meter                                                                                              (top down view)
                                                               4. Manifold to basin tree 4” PVC to three PVC lines (two 2-inch and one 1-inch)                                                  2’                                         Surface area on  2
                                                               5. Float valve 1 opens at H O < 3.0’ depth                                                                                                                                  ground is 180 in
                                                                                                  2
                                                               6. Float valve 2 opens at H O < 2.5’ depth
                                                                                                  2
                                                               7. Float valve 3 opens at H O < 2.0’ depth
                                                                                                  2
                                                               8. Optional Float valve 4 closes when water tank is full



                                                                                                                                                                                                      Basin Tree Detail







                                                                  Not to Scale


                                                                                                                                                                                                                                                       Figure 3

                                                                                                                                                                                                                                                 Infiltration Test
                                                                                                                                                                                                                                          Process Flow Diagram





                                                                                                                Yucaipa Groundwater Sustainability Agency - March 14, 2018 - Page 67 of 226